Cables | Kinds Content | Thermoplastic insulated cables

PE/Multipairs/IS/OS/PVC/PUR/LS0H (M1)

  • EG

PE insulated multipair cables with single and global screen
Thermocouple, extension, compensating quality or RTD cables
Working temperature: -30 + 70 °C
Insulation resistance: >5000 Mohm x km

Reference Standards

  • IEC 584 parte 1,2,3
  • DIN 43710 – DIN 43714
  • ASTM E230 (ANSI MC96.1-1982)
  • CEI 20 – 11

Construction

  • Solid or stranded conductors
  • Insulation: flame retardant PE
  • Core laying – up : conductors twisted in pairs
  • Pair identification: numbered tape
  • Pair screen: aluminium – polyester bonded tape with tin plated copper drain wire
  • Global screen: aluminium – polyester bonded tape with tin plated copper drain wire
  • Outer jacket: flame retardant PVC or PUR or LS0H (M1)
  • Cable end – form cross section: round cable
  • Standard packing: wooden drum
  • Lowest quantity that may be ordered. 250 Metres


PE-armoured+galvanized steel wire armoured/PVC/PUR/LS0H (M1)

  • EW

PE insulated, screened, armoured multipair cables
Thermocouple, extension, compensating quality or RTD cables
Working temperature: -30 + 70 °C
Insulation resistance: >5000 Mohm x km

Reference Standards

  • IEC 584 parte 1,2,3
  • DIN 43710 – DIN 43714
  • ASTM E230 (ANSI MC96.1-1982)
  • CEI 20 – 11

Construction

  • Stranded conductors
  • Insulation: flame retardant PE
  • Core laying – up: conductors twisted in pairs
  • Pair identification: printed number on insulated conductors
  • On request global screen: aluminium – polyester bonded tape with tin plated copper drain wire
  • Inner jacket: flame retardant PVC or PUR or LS0H (M1)
  • Armour: galvanised steel wire armour
  • Outer jacket: flame retardant PVC or PUR or LS0H (M1)
  • Cable end – form cross section: round cable
  • Standard packing: wooden drum
  • Lowest quantity that may be ordered: 250 Metres


PVC insulated oval

  • PA - oval

PVC insulated oval cables
Thermocouple, extension, compensating quality or RTD cables
Working temperature : -30 + 80/105°C
Insulation resistance: > 20 Mohm x km ( measured at 1000 Volt dc – at 20 °C)

Reference Standards

  • IEC 584 parte 1,2,3
  • DIN 43710 – DIN 43714
  • ASTM E230 (ANSI MC96.1-1982)
  • CEI 20 – 11

Construction

  • Solid or stranded construction
  • Insulation: PVC
  • Core laying – up : flat twin
  • Outer jacket: PVC
  • Cable end – form cross section: flat/oval cable
  • Standard packing: drums, spools or coils


PVC - PVC twisted

  • PA - twisted

PVC insulated twisted cable
Thermocouple, extension, compensating quality or RTD cables
Working temperature: -30 + 80/105°C
Insulation resistance: > 20 Mohm/km ( measured at 1000 Volt dc – at 20 °C)

Reference Standards

  • IEC 584 parte 1,2,3
  • DIN 43710 – DIN 43714
  • ASTM E230 (ANSI MC96.1-1982)
  • CEI 20 – 11

Construction

  • Stranded conductors
  • Insulation: PVC
  • Core laying – up: twisted conductors
  • Outer jacket: PVC
  • Cable end – form cross section: round cable
  • Standard packing: spools or coils