Heater | Cables | Kinds Content | Glassfibre

Stainless Steel Armoured - Oval

  • VC-oval

Glassfibre insulated, stainless steel armoured cables
Thermocouple, extension, compensating quality or RTD cables
Working temperature: + 400°C type “E” ; + 650°C R/S (HT)
Insulation resistance: > 20 Mohm x km ( measured at 1000 Volt dc – at 20°C)

Reference Standards

  • IEC 584 parte 1,2,3
  • DIN 43710 – DIN 43714
  • ASTM E230 (ANSI MC96.1-1982)
  • CEI 20 – 11

Construction

  • Solid or stranded conductors
  • Insulation: braided glassfibre type “E” or “R”
  • Impregnation: liquid silicon rubber
  • Core laying – up: flat twin
  • Inner braid: glassfibre silicon – vinyl impregnation
  • Outer armour: stainless steel wire braid AISI
  • Cable end – form cros section: flat/oval cable
  • Standard packing: drums, spools or coils